BatteryHub
Energy budgets for sensors and backup power
Free to read · Reviewed 2026-10-21
This feature estimates scenario runtime from average energy balance. It requires usable battery-terminal DC energy for a defined operating window and does not read or identify your battery automatically.
Start from the ROE guest workbench to try the public features in this guide without signing in. Calculations and report access still follow the displayed quota and authorization steps. Private research projects, the knowledge library, and full datasets require membership and the relevant permissions.
Steps
- Open Backup / IoT runtime and duty cycle.
- First try the teaching example: usable 100 Wh, active 20 W, standby 5 W, active fraction 20%, efficiency 80%, additional 0 W, target 8 hours. Label the source “Teaching demonstration, not my battery measurement”. Check for double-counted losses and the current billing mode at the top.
- Confirm conditions and start calculation; view runtime, energy margin, and duty-cycle scenarios in the job record.
Teaching example
100 Wh, 20 W active, 5 W standby, 20% active, 80% efficiency, and 0 W additional yield 8 W average load and 10 W battery-terminal power, for 10 hours of scenario runtime. An 8-hour target requires 80 Wh, leaving +20 Wh. This is a fixed-formula example, not a live run result.
What to examine
First examine average load and battery-terminal power, then runtime and energy margin for the 8-hour target. Only call displayed values your run results after your job completes; this example has not been executed for you.
Next step
Keep other demonstration values fixed, change only active fraction, and compare runtime/margin. For your sensor, first establish the usable Wh source and applicability. If missing, ask only for usable battery-terminal Wh and its evidence, then progressively check other required fields instead of asking the entire list at once.
Check for a real scenario
- Usable Wh, source, temperature, discharge rate, cutoff window, and health state.
- Load-side active/standby average W and active-time percentage.
- One-way battery-to-load conversion efficiency (%).
- Additional battery-side W not already included in load or efficiency, and target duration (h).
Limits
Usable Wh is not multiplied again by SoC, SoH, or reserve. The model excludes peaks, voltage drop, BMS, self-discharge, and temperature change. Positive margin is not a safety or reliable-supply guarantee. Zero power has no finite runtime estimate and must not be called infinite runtime.
Start with your question when measurement conditions are known
For example, if measured usable energy is 20 Wh at 25°C under a specified discharge rate and cutoff window, and you want to compare 10% and 20% sensor duty cycles, preserve these conditions and the Wh source in the energy budget. Temperature documents the input basis; the model does not infer available energy at another temperature.
Check active/standby power, efficiency, and additional losses before comparing duty cycle. Unprovided efficiency/losses are not measurements. Winter versus room-temperature comparisons need separately applicable Wh evidence or another validated temperature model. To find temperature data, first consult the battery dataset catalog. This is an operating scenario, not a completed job or battery safety assessment.
Check whether room-temperature Wh applies in the cold
The public sources below, reviewed on 2026-10-09, support condition review only, not matching or validating your battery. A report measured at 25°C cannot supply usable Wh at −10°C merely because a product has an operating-temperature range. Missing evidence also does not prove the task must fail. No cold-temperature Wh or universal derating factor is inferred.
First ask one question: privately check the battery manufacturer, model, chemistry, and original Wh report. Examine existing labels, specifications, and records; no complete private report need be pasted into AI/public MCP. Then compare evidence and use case one condition at a time, preserving unknowns:
- Battery identity: do manufacturer, model, chemistry, and cell/pack configuration match? Do not infer from voltage or Wh. Source S1.
- Actual temperature: distinguish ambient-air and battery temperature and check startup, equilibration, and operation records. Sources S1/S2.
- Load and cutoff: compare active/standby load, pulse peaks/durations, duty cycle, report stop criteria, protection cutoff, and device minimum voltage. Equal averages do not remove pulse limits. Sources S1/S3.
- Energy boundary: identify cell terminals, pack output, or regulated load side, including whether efficiency and always-on losses are already counted. Aligning supply/demand boundaries and avoiding double counting is engineering accounting inferred from S3, not measured efficiency for this device.
- Initial state/history: check charge/remaining energy, preparation/rest, storage, age, and use/cycle records. Establish chemistry first; do not assume rechargeability or instruct charging an unknown battery. Sources S1/S2.
- Method/uncertainty: privately inspect original reports/curves, methods, instruments, samples/repeatability, and documented uncertainty/resolution. Do not invent error bands. S4 supports reviewing method implementation only, not assuming the report used a standard method.
Original sources and their limits
- S1: Energizer Cylindrical Primary Lithium Handbook and Application Manual, ©2018; printed pages 4–5 “Temperature Effects on Performance”, 11–13 “Capacity”, 14 “Shelf Life”. Supports checking temperature, load, cutoff, pulse duty cycle, and storage for this Li/FeS₂ family. It does not identify your battery or provide its cold Wh, universal derating, or mission reliability. Do not transplant charts or numerical limits.
- S2: INL Battery Test Manual for Electric Vehicles, Revision 3, 2015-06, INL/EXT-15-34184; §3.1.2 printed page 4, §3.1.5 pages 4–5, §3.2 page 5, §3.7 page 13, §§4.2–4.2.2 page 24, §4.7 page 38. Supports explicit temperature/equilibration, initial state, stop criteria, and capacity/energy distinction. Reported capacity alone does not establish application Available Energy targets. This is not a qualification standard or test recipe for an unknown sensor battery; do not apply automotive test values.
- S3: Texas Instruments Extending Battery Life With Low Quiescent Current and Dynamic Voltage Scaling, SLVAER8A, 2020-04, revised 2020-10; §1 pages 2–3, §2 page 4 table 2-2. Supports distinguishing active/standby, efficiency, supply-circuit consumption, and input/load boundaries. It establishes neither this device's losses, chemistry, nor temperature behavior and is not a hardware recommendation.
- S4: NIST Technical Note 1297, 1994-09, appendix D.4.1. Discusses measurands defined by standard methods, including repeatability/reproducibility and implementation uncertainty. It does not prove your method, supply a Wh error or accuracy threshold, or certify an experiment.
Both prepare_energy_budget and interpret_energy_budget_result attach the same evidence_review_plan: one first_question, six source-linked checks, and four source cards. Existing input formats, missing-value questions, and numerical checks remain unchanged. The checklist reads no private data, fetches no URLs, and creates no analysis or experiment. Cold applicability remains unresolved until existing evidence matches battery, temperature, load, initial state, cutoff, and boundary. Confirm current capabilities through tools/list.
Structured scenario preparation
This version provides the read-only prepare_energy_budget tool. Check capabilities through tools/list after connecting. The existing six public reading/guidance tools retain their input contracts.
For your average-energy scenario, AI may submit goal, energy_input, and labeled context only after you explicitly choose to provide them. Missing values remain unknown; Wh is not guessed from prose and demonstration defaults are not inserted. The response lists missing fields, units, and one next question. Unknowns can remain in a new project draft for review. Only complete, numerically valid inputs additionally produce the existing energy-application input; sources and assumptions remain independently unverified.
This is a public tool: never send keys, cookies, private project identifiers, or context you did not choose to provide. It processes only supplied content; it does not read member data, save, quote, execute, or produce a new runtime result. Tool statelessness does not imply zero infrastructure retention or logging.
BatteryHub supports private project handoff. In a compatible, authenticated interface, users must review, save, and explicitly submit; existing billing and permissions apply. Preparation provides no private MCP read/write/execute, result interpretation, or server-side continuation. Inputs awaiting review are not saved or calculated. C011 separately offers bounded interpretation of a user-provided minimal result copy, described below.
From AI draft to private project
- In a compatible MCP actually providing prepare_energy_budget, ask AI for the exact JSON of the response's project_import object. Copy that object only, not the entire response or project_draft_payload. It contains format, version, and draft, with no account, project identifier, or execution authorization.
- In authenticated BatteryHub research projects, paste and preview it. Review goal, values/units, source text, and fact claims, assumptions, unknowns, and AI inference separately. Labels remain independently unverified; correct format does not authenticate MCP provenance.
- Explicit acceptance creates only a new unsaved draft. Decide whether to discard existing unsaved edits first; cancellation preserves them. Unknowns remain unknown, no sample numbers are added, and existing saved projects are not overwritten.
- Use the existing save control when ready. Complete and save before explicitly loading analysis; the original submit button still controls execution. Pasting, preview, and import do not create a project, quote, or job or send private data back to AI.
Use this import interface after signing in. Never paste keys or credentials. Source URLs remain text and are not fetched. Import grants no private MCP read/write or server continuation; C011 result-copy interpretation is a separate explicit disclosure step.
Bring a completed result back to your AI
This version offers read-only interpret_energy_budget_result; confirm with tools/list.
- In a compatible authenticated private project, select a completed saved analysis with a supported method and open result-handoff review. It uses that run's saved input and result, never fills from the current draft.
- Review seven numeric inputs, four result fields, units, and claimed method version/code fingerprint. Account/project/job IDs, names, goal, timestamps, full sources, and context are omitted. A local version hint helps identify the selection and is not sent to AI.
- Numbers and fingerprints may still be confidential; omission of identifiers is not anonymity. Decide whether and to which AI to disclose, then explicitly copy. The website writes only the local clipboard and does not send automatically to AI/MCP. Closing cannot revoke an already started clipboard write.
- If you choose to share, provide the reviewed batteryhub.energy-result JSON as the tool's result parameter. Calling the public tool discloses those selected numbers; AI, network, and providers may retain content. Add no keys, private identifiers, full sources, or conversations.
- The tool checks format, supported versions, and bounded arithmetic consistency, then explains the supplied conditional target margin. If inconsistent, check the original saved result; it does not repair or create jobs. Omitted sources and applicability remain unknown; verify privately when needed instead of sharing all original text.
SHA, completed status, and numerical consistency do not authenticate server provenance or measured evidence. Positive margin guarantees neither actual success, safety, nor reliability. Null runtime at zero average power is not infinite runtime. The tool does not retrieve private results, save, quote, execute, or forward automatically. This is bounded copy interpretation, without private MCP login/read/write/continuation or automatic saving of reasoning.
Bring a saved comparison judgment back to AI
The ninth read-only tool, interpret_energy_budget_comparison, accepts only an explicitly provided batteryhub.energy-comparison version 1 copy. Confirm current capabilities through tools/list.
- In a compatible authenticated private project, reopen your saved comparison. Save or discard unsaved edits first, then review its AI copy. It uses that comparison's saved baseline, alternative, and assessment, not the latest analysis, current draft, or separate current-rule check.
- Review both sets of values/units, saved direction, historical status/margins, and reasoning. Reason and next step are each omitted by default; only individually selected original saved text is included. Read exact text and the complete read-only JSON. Private IDs, names, goal, sources/context, times, history, digest, and original blocking text are always omitted, but selected text may still reveal private information. Do not include credentials or unnecessary private content.
- Confirm review of the actual JSON, selected text, and omissions, then copy the reviewed comparison JSON. Switching comparison/version, closing, or changing text selection requires review again. If copying fails, manual selection remains possible. The website only writes the local clipboard, never automatically sends to AI/MCP; a started write cannot be withdrawn.
- Decide whether and to which AI to provide the complete envelope as comparison. The tool checks both original C011 value sets and saved historical margins. Reason and next step remain unverified data; embedded commands/URLs are neither executed nor fetched. AI and providers may retain your chosen copy.
- Historical comparability remains a supplied claim. Omitted sources/goals/context prevent reconstructing complete compatibility or scientific applicability. Blocked comparisons retain null margins: no guessed blocking reason, winner, or unknown-margin calculation. Inconsistency, unknown versions, or envelopes above 12 KiB are rejected; check the original private comparison instead of automatic repair.
If you include reason or next step, AI may ask about existing evidence and unknowns to check privately. If both are omitted, it first states that original intent was not provided and asks which question to continue. Generic evidence lists are optional background, not substitutes for your specific efficiency question. The tool does not retrieve private comparisons, save, quote, execute, fetch sources, or forward; it grants no new private MCP permissions or server continuation.
Private workspace export and restorable archive
In a compatible BatteryHub project, use export and restorable archive. Check the selected project, full history count, and retention scope, then explicitly download the private workspace file. It includes original text, identifiers, intended recipients, and every saved version, beyond the screen's recent 100 records / 20 versions. It is not the minimal AI copy, anonymous data, or a full account backup; do not paste it directly into AI. Download original run artifacts separately from your job. Files over 32 MiB are rejected, never presented as successfully truncated exports.
Archiving is reversible hiding, not deletion or capacity release, and does not cancel jobs or refund charges. Original history, artifacts, billing, backups, and earlier copies remain. Explicitly export or restore from the archive list; review anew after restoration rather than reusing old copy consent. Limits are 100 projects per person including archived projects, 16 MiB complete records per project, and 64 MiB per person, separate from calculation quota. There is no automatic expiry/permanent purge or permanent-backup promise; existing environment-reset rules still apply. Actual deployment/browser acceptance requires separate verification; a guide does not establish production availability.