Compare cross-cell impedance with built-in EIS spectra

Free to read · Reviewed 2026-10-21

To understand electrochemical impedance spectroscopy (EIS), open impedance and quality consistency and compare impedance spread at matching conditions and frequencies across eight built-in cells. This is an exercise with measured cross-cell data, not a quality judgment about your battery.

Start from the ROE guest workbench to try the public features in this guide without signing in. Calculations and report access still follow the displayed quota and authorization steps. Private research projects, the knowledge library, and full datasets require membership and the relevant permissions.

Steps

  1. Open Impedance and quality consistency . Production eligibility and quota rules apply.
  2. If prompted to obtain a research report, check quota and pricing at the top and decide whether to obtain it. No reusable entitlement does not mean the feature is absent; reading this MCP guide does not obtain a report.
  3. After loading, examine eight LR2032 cells, 25C01–25C08, each with 60 matching frequencies. No upload is required. The bottom fit-and-save button starts a separate computation and is unnecessary here.
  4. Under frequency-by-frequency standard deviation and outlier thresholds, keep comparison frequency 952.86591 Hz and real component Re(Z). Read mean and sample standard deviation, then each cell's exploratory threshold relative to the other seven.

What to examine

The built-in example's real-part mean ± sample standard deviation at 952.86591 Hz is about 0.46677 ± 0.02045 Ω. These are report example values, not live MCP measurements or DC internal resistance. Nyquist plots show Re(Z) versus −Im(Z), while imaginary-component statistics use signed Im(Z); keep signs distinct.

The example has zero cell/frequency pairs above the full-spectrum threshold. This means only that none exceed this exploratory threshold, not that quality passed. Hiding a curve in the legend does not change the statistical sample. Impedance at different frequencies is not the same physical quantity and cannot be pooled into one standard deviation.

Next step

Select signed imaginary component Im(Z), then change only one comparison frequency to see where differences concentrate. Read methods and sources and download the 60-frequency statistics CSV. For models fitted to one spectrum, see Dual-branch CPE fitting; cross-cell statistics and fitting are distinct.

For your own cells, first ask whether spectra were measured at matching SoC, temperature, and settings. Establish comparability before reviewing other necessary data. This workflow does not promise automatic report reconstruction from arbitrary uploads.

Limits

These exploratory data use the same model, 25°C, 15 minutes of rest after the charging endpoint, and 5 mA excitation. They do not establish identical microstructure, equal actual SoH, or factory-new cells. The small sample lacks same-state repeated measurements to separate variability; thresholds are not acceptance specifications. All eight cells already participated in exploration and fitting and are not an unused independent validation group. Model fits and theoretical material sensitivity cannot replace measured validation; see Research limits. MCP does not read member data, obtain reports, or create jobs.